Schneider 16966 125A 2 Pole RCCB Specification

  • Finish Type
  • Matt
  • Automation Grade
  • Manual
  • Response Time
  • < 200 ms
  • Mechanical Life
  • > 5000 operations
  • Rated Voltage
  • 240/415V AC
  • Circuit Type
  • AC (Type A)
  • Max. Current
  • 125A
  • Number of Module
  • 2 Modules
  • Temperature Range
  • -5C to +40C
  • Protection Level
  • IP20
  • Product Type
  • RCCB (Residual Current Circuit Breaker)
  • Material
  • High Impact Flame Retardant Plastic
  • Insulation Resistance
  • 100 M at 500V DC
  • Contact Resistance
  • 100 m
  • Max. Voltage
  • 240/415V AC
  • Operating Temperature
  • -5C to +40C
  • Stoke
  • Manual
  • Size
  • Standard Modular (approx. 90mm x 80mm x 75mm)
  • Color
  • White & Green
  • Weight
  • Approx. 0.45 kg
  • Mounting Type
  • DIN Rail
  • Current Rating
  • 125A
  • No Of Poles
  • 2 Pole
  • Rated Residual Operating Current (In)
  • 30mA
  • Isolation Function
  • Yes
  • Standards Complied
  • IEC/EN 61008-1
  • Endurance
  • Electrical: 2000 cycles, Mechanical: 5000 cycles
  • Suitable for Neutral and Phase
  • Yes
  • Rated Short Circuit Making Capacity
  • 1500A
  • Test Button
  • Available
  • Breaking Capacity
  • 6kA
  • Frequency
  • 50/60 Hz
  • Terminal Capacity
  • up to 35 sq. mm
  • Trip Sensitivity
  • 30mA
  • Dimensions (W x H x D)
  • 36mm x 80mm x 75mm
 

Schneider 16966 125A 2 Pole RCCB Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 10000 Pieces Per Month
  • Delivery Time
  • 7-10 Days
  • Main Domestic Market
  • All India
 

About Schneider 16966 125A 2 Pole RCCB



The Schneider 16966 125A 2 Pole RCCB is a cost-effective yet redoubtable solution for superior electrical safety. Featuring sensational trip sensitivity (30mA) and a remarkable breaking capacity of 6kA, this uncommon device offers unparalleled protection for both neutral and phase circuits. Select this RCCB for access to advanced safety standards (IEC/EN 61008-1) and a robust insulation resistance of 100 M at 500V DC. Its high-impact flame-retardant plastic design ensures longevity, while a matt finish and standard modular size allow seamless installation in diverse settings. Ideal for suppliers and traders across India.

Versatile Applications and Installation

Ideal for surface-mounted and DIN rail installation, the Schneider 16966 125A 2 Pole RCCB is extensively used by contractors, electricians, and plant managers in industrial and commercial environments. Its robust insulation and reliable operation make it optimal for plant applications where neutral and phase circuit protection is essential. This RCCB delivers exceptional safety and performance, making it a select choice for critical infrastructure and high-capacity electrical systems.


Prompt Delivery and Accredited Assurance

With a domestic market rate, Schneider ensures secure shipping for the 16966 125A 2 Pole RCCB. Certified to IEC/EN 61008-1 standards, the product upholds industry-leading safety requirements. Samples may be available on request, enabling customers to evaluate before a bulk purchase. Enjoy quick delivery times and peace of mind, knowing each device arrives in optimal condition, backed by a supplier trusted throughout India.


FAQ's of Schneider 16966 125A 2 Pole RCCB:


Q: How does the Schneider 16966 125A 2 Pole RCCB enhance safety in electrical installations?

A: This RCCB detects residual currents swiftly with a trip sensitivity of 30mA, disconnecting circuits in under 200 ms. This rapid response protects users from electric shocks and prevents fire hazards.

Q: What applications is the 125A 2 Pole RCCB best suited for?

A: The device is ideal for industrial plants, commercial complexes, and residential setups that require robust phase and neutral circuit protection and high endurance for both mechanical and electrical operations.

Q: Where can I source Schneider 16966 RCCBs in India?

A: The product is widely available through certified suppliers and traders across India. Contact your local electrical equipment distributor or authorized Schneider partner.

Q: When can I expect the delivery if I place an order for this RCCB?

A: Typically, Schneider ensures prompt delivery within standard timeframes across the domestic market. Delivery times may vary depending on your location and stock availability.

Q: What certifications does the Schneider 16966 RCCB comply with?

A: It complies with IEC/EN 61008-1, ensuring it meets rigorous international safety and performance standards for residual current devices.

Q: How can I request a sample of the Schneider 16966 RCCB?

A: Samples may be available upon request from your supplier or Schneider's authorized dealers, helping you evaluate the product before making a bulk purchase.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Electric RCCB Category

LAndT BC406303 Tripper 63A RCCB

LAndT BC406303 Tripper 63A RCCB

Price 2500 INR / Piece

Minimum Order Quantity : 1 Piece

Current Rating : 63A

Size : Standard DIN Rail Mount

Temperature Range : 25C to +70C (Storage)

Color : White/Grey

Schneider Electric Easy9 RCCB 63 A, 4 Pole, 30 mA, Type AC | EZ9R35463

Schneider Electric Easy9 RCCB 63 A, 4 Pole, 30 mA, Type AC | EZ9R35463

Price 2800.0 INR / Piece

Minimum Order Quantity : 3 Pieces

Current Rating : 125A

Size : Standard DIN rail mount (approx. 90 mm x 72 mm x 80 mm)

Temperature Range : 5C to +40C

Color : White/Grey



Back to top